MTD 249-645A Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
L
L
L
<
}
X X X
STOP-START HAND SWITCH MOMENTARY CONTACT SWITCHES
ON AND OFF EVENT LIGHTS
(CONTROLLED DEVICE WILL NOT RESTART ON RETURN
OF POWER AFTER POWER FAILURE).
VOLTAGE
FREQUENCY
CURRENT
PNEUMATIC
PULSE FREQUENCY
PULSE DURATION
DIGITAL
ANALOG
CURRENT TO PNEUMATIC
TRANSDUCER (BACK OF
RESISTANCE
HYDRAULIC
YL
OO
HS
OO
HS
SS
ON-OFF HAND SWITCH. MAINTAINED CONTACT SWITCH
(CONTROLLED DEVICE WILL RESTART ON RETURN OF
POWER AFTER POWER FAILURE).
(*)
(+)
PACKAGE SYSTEM
EQUIPMENT
= GATE
= AIR RELEASE VALVE
= EJECTOR
= MECHANICAL EQUIPMENT
= AIR AND VACUUM RELEASE VALVE
AVRV
E
G
M
P
D:
PANEL, IN A FLOW LOOP)
FIELD MOUNTED
REAR-OF-PANEL MOUNTED
(OPERATOR INACCESSIBLE)
PANEL MOUNTED
(OPERATOR ACCESSIBLE)
MCC MOUNTED
3 TYPICAL SETS OF
2 SIGNALS EACH.
TOTAL OF 6 SIGNALS.
INTERFACE TO OR FROM
PROCESS EXTERNAL TO
PROJECT
NON-CONNECTING
LINES
PROCESS OR
INITIATING VARIABLE
READOUT OR
PASSIVE FUNCTION
GLASS, GAUGE
VIEWING DEVICE
TIME RATE
OF CHANGE
VIBRATION, MECHANICAL
ANALYSIS
VALVE, DAMPER,
LOUVER
EVENT, STATE OR
PRESENCE
RELAY, COMPUTE,
CONVERT
DRIVE, ACTUATOR,
UNCLASSIFIED FINAL
CONTROL ELEMENT
POINT (TEST)
CONNECTION
RATIO
(FRACTION)
INTEGRATE,
TOTALIZE
MIDDLE,
INTERMEDIATE
= PROCESS INTERFACE
= SIGNAL INTERFACE
A
D
S
= DESTINATION DRAWING NO.
= SOURCE DRAWING NO.
AC
AM
AUTO-MANUAL
AFD
CCS
2
CM
COMPUTER-MANUAL
COD
CHEMICAL OXYGEN DEMAND
CP-X
CONTROL PANEL NO. X
DC
DIRECT CURRENT
DO
DISSOLVED OXYGEN
FREE CHLORINE RESIDUAL
FCL
2
FOS
FAST-OFF-SLOW
FOSA
FAST-OFF-SLOW-AUTO
FOSR
FAST-OFF-SLOW-REMOTE
FP-W-X
FR
FORWARD-REVERSE
HOA
HAND-OFF-AUTO
HOR
HAND-OFF-REMOTE
LEL
LOWER EXPLOSIVE LIMIT
LOS
LOCKOUT STOP
LR
MA
MC
MCC-X
OC
OCA
OO
OOA
ORP
OSC
LOCAL-REMOTE
MANUAL-AUTO
MODULATE-CLOSE
MOTOR CONTROL CENTER NO. X
OPEN-CLOSE (D)
OPEN-CLOSE-AUTO
ON-OFF
ON-OFF-AUTO
OXIDATION REDUCTION POTENTIAL
OPEN-STOP-CLOSE
pH
RM-X
HYDROGEN ION CONCENTRATION
REMOTE MULTIPLEXING MODULE NO. X
CENTRAL CONTROL SYSTEM
OCR
OOR
OPEN-CLOSE-REMOTE
ON-OFF-REMOTE
AVG
SUM
SSC
TCL
2
TURB
VIB
VIBRATION
SUPERVISORY SET POINT CONTROL
TOTAL CHLORINE RESIDUAL
TURBIDITY
DIFFERENCE
MULTIPLY
X
DIVIDE
CHARACTERIZED
SQUARE ROOT
AVERAGE
SELECT HIGHEST SIGNAL
SELECT LOWEST SIGNAL
f(x)
REMOTE TELEMETRY UNIT NO. X
RTU-X
SF
SS
SLOWER-FASTER
START-STOP
BIAS
PROCESS OR SIGNAL LINE
CONTINUATION N=1,2,3,ETC
N N
S
A
D
DCS
DISTRIBUTED CONTROL SYSTEM
DCU
DISTRIBUTED CONTROL UNIT
PLC
PROGRAMMABLE LOGIC CONTROLLER
ISR
INTRINSICALLY SAFE RELAY
PROCESS (OPEN CHANNEL)
PNEUMATIC SIGNAL
FILLED SYSTEM SIGNAL
CONNECTING LINES
HYDRAULIC SYSTEM SIGNAL
BUILDING OR
FACILITY BOUNDARY
PROCESS (CLOSED CONDUIT,
DASHED LINE INDICATES
ALTERNATE FLOW STREAM)
ANALOG SIGNAL
(4 TO 20 mAdc, ETC.)
DISCRETE SIGNAL
(ON/OFF, ETC.)
DATA LINK
MSC
MANUFACTURER SUPPLIED CABLE
FIRST LETTER(S)
SUCCEEDING LETTER(S)
CLARIFYING ABBREVIATIONS
(A)
(B)
(2)
3(2)
PARALLELING LINES
(A)
TOTAL OF 2 SIGNALS
(B)
BB
CL etc.
UNIT NUMBER
FY
A
D
E
F
P
PF
PD
R
I/P
H
I
LETTER
MODIFIER
OUTPUT FUNCTION
MODIFIER
A
B
C
D
E
F
G
H
DENSITY (S.G)
VOLTAGE
FLOW RATE
HAND (MANUAL)
POWER
LEVEL
MOTION
TEMPERATURE
POSITION
ALARM
DIFFERENTIAL
CONTROL
GATE
HIGH
INDICATE
SCAN
CONTROL STATION
LIGHT (PILOT)
LOW
RECORD OR PRINT
SAFETY
SWITCH
TRANSMIT
WELL
ANALYSIS (+)
UNCLASSIFIED (+) UNCLASSIFIED (+)UNCLASSIFIED (+) UNCLASSIFIED (+)
BURNER, COMBUSTION
MOMENTARY
ORIFICE, RESTRICTION
PRESSURE, VACUUM
QUANTITY
RADIATION
SPEED, FREQUENCY
WEIGHT, FORCE
X AXIS
Y AXIS
Z AXIS
!
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
FIRST-LETTER
SUCCEEDING-LETTERS
PRIMARY ELEMENT, SENSOR
TORQUE
MULTIVARIABLE
MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION
WHEN USED, EXPLANATION IS SHOWN ADJACENT TO INSTRUMENT SYMBOL. SEE ABBREVIATIONS AND LETTER SYMBOLS.
TABLE BASED ON THE INSTRUMENTATION, SYSTEMS, AND AUTOMATION SOCIETY (ISA) STANDARD.
WHEN USED, DEFINE THE MEANING HERE FOR THE PROJECT
COMPUTER FUNCTION
PLC FUNCTION
= PUMP
= TANK
T
ARV
RIO
REMOTE I/O UNIT
GENERAL INSTRUMENT
OR FUNCTIONAL SYMBOLS
EXAMPLE SYMBOLS
INSTRUMENT IDENTIFICATION LETTERS TABLE
EXAMPLE:
TRANSDUCERS
SPECIAL CASES
INSTRUMENT IDENTIFICATION
LINE LEGEND
SELF CONTAINED VALVE &
GENERAL NOTES
EQUIPMENT TAG NUMBERS
INTERFACE SYMBOLS
>
SHARED DISPLAY,
SHARED CONTROL
ALTERNATING CURRENT
A
LOOP NUMBER
CURRENT (ELECTRICAL)
TIME, TIME SCHEDULE
PPLU
PROCESS NUMBER
FIT
USER’S CHOICE (*)USER’S CHOICE (*)
= INTERFACE LETTER
D-XXXX
XXXX
= EQUIPMENT NUMBER
USER’S CHOICE (*)
USER’S CHOICE (*)
USER’S CHOICE (*)
USER’S CHOICE (*)
USER’S CHOICE (*)
USER’S CHOICE (*)
USER’S CHOICE (*)
ISB
INTRINSICALLY-SAFE BARRIER
MF
MICROFILTER
MS
MOTOR STARTER
ADJUSTABLE FREQUENCY DRIVE
RPM
REVOLUTIONS PER MINUTE
REM
REMOTE
LCP
LOCAL CONTROL PANEL
HMI
HUMAN-MACHINE INTERFACE
CHLORINE (TYPICAL: USE STANDARD CHEMICAL
ELEMENT ABBREVIATION)
X = PANEL NUMBER)
FIELD PANEL NO. WX (W = UNIT PROCESS NUMBER
ABBREVIATIONS &
LETTER SYMBOLS
COMPONENTS AND PANELS SHOWN WITH A SINGLE DIAMOND ( )
ARE TO BE PROVIDED AS PART OF THE PROCESS
INSTRUMENTATION AND CONTROL SYSTEM.
COMPONENTS AND PANELS SHOWN WITH A DOUBLE
ASTERISK ( ) ARE TO BE PROVIDED AS PART OF A
PACKAGE SYSTEM.
THIS IS A STANDARD LEGEND. THEREFORE, NOT ALL OF THIS
INFORMATION MAY BE USED ON THIS PROJECT.
1.
2.
3.
177889
W PEARSON
APPROVED-BY
CHECKED-BY
LEGEND
GENERAL
NO
DESCRIPTION
DATE
N
APVR
BAYOU LAFOURCHE
PROCESS AND INSTRUMENTATION
G-11
11
M DUNN
PROJ
DATE
DATE
NO.
DSGN
DR
REVISION
CHK
APVD
BY
APVD
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF
CH2M HILL AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CH2MHILL.
REUSE OF DOCUMENTS:
c
SHEET
DWG
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
0
1"
CH2M HILL 2004. ALL RIGHTS RESERVED.
1 2 3 4 5 6
A
B
C
D
ISSUED FOR 30% REVIEW
APVR
N
DATE
DESCRIPTION
NO
SEPT 2005
MISSISSIPPI RIVER
WATER REINTRODUCTION
INTO BAYOU LAFOURCHE PHASE 2
LOUISIANA DEPARTMENT OF
NATURAL RESOURCES
PRELIMINARY
NOT FOR
CONSTRUCTION
Vista de pagina 5
1 2 3 4 5 6 7 8 9 10 11 ... 14 15

Comentarios a estos manuales

Sin comentarios