1. Operating instructions
1.1 Unit description
The hydraulically controlled pressurized Small-Instantaneous Water Heater is designed to heat water for one
draw off point. When the draw-off fitting is opened, the heating capacity switches on automatically and the
water is heated. The hot water output is dependent on the cold water temperature, the heating capacity, and
the flow rate.
1.2 The most important points in brief
Temperature adjustment is effected using the fitting:
To increase the temperature, restrict the flow rate a little.
For low temperatures, increase the flow rate or mix in cold water.
1.3 Hot water output
Typ Leistung bei 230 V Warmwasserleistung*
MTD 350 3,5 kW 2,0 l/min
MTD 440 4,4 kW 2,5 l/min
MTD 570 5,7 kW 3,3 l/min
* The built-in automatic flow regulation provides a constant flow rate. Temperature increase of about 25 K.
1.4 Safety instruction
In the case of temperature selection, water temperatures of over 60 °C can be reached at the hot water
outlet.
If it is intended that children or people with restricted physical, sensory or mental capabilities are to ope-
rate the appliance, they must only be permitted to do so after appropriate instruction has been provided
by the person responsible for their safety.
Children should be supervised to ensure that they do not play with the device.
Risk of scalding!
1.5 Important notes
If the water feed of the MTD has been interrupted - e.g. because of the danger of frost or work on the
water pipe, the following steps must be taken before the unit is brought back into operation:
1. Remove or switch off fuses.
2. Open a tap downstream of the unit until the unit and the cold water feed pipe are free of air.
3. Replace or switch on fuses again.
1.6 Maintenance and care
Maintenance work, such as for example checking the electrical safety, may only be carried out by a qualified
installer.
A damp cloth is sufficient for care of the unit. Do not use any abrasive or corrosive cleaning agents.
Please de-scale or replace the enclosed jet regulator „SR“ regularly:
MTD 350 / MTD 440: SR 3 Best.-Nr. 14 35 02
MTD 570: SR 5 Best.-Nr. 27 05 82
1.7 First actions to be taken in the event of malfunction
.. . First actions to be taken in the event of malfunction „Please look up: „3. Fault finding by the user“
page 14.
In the event of maintenance and possibly repair work please inform the qualified installer of the data on the
identification plate (
A
12):
MTD . . .
Model:
. . . . . .
E-Nr:
F-Nr:
. . . . . . . .
1.8 Operating and installation instructions
Keep these instructions carefully and pass them on to your successor in the event of a change in ownership,
in the event of maintenance and possible repair work they should be passed to the qualified installer for his
attention.